Showing 1–24 of 30 results
-
RO21 Industrial Reverse Osmosis System
Technical Data:Price on request Read more- Output from 50 to 450 liters / hour ( 15°C water temp. )
- Stainless steel membrane housing
- Membrane Type 2521 and 4021 IEM
- Rotary vane pump 230V AC Type P210
Type Output Liters /h Voltage Power draw ( without options )
Weight approx. kg Dimensions W x D x H in mm RO2521 50 235W 230V 50Hz 40 400 x 400 x 850 RO4021 100 RO4021 150 550W 230V 50Hz 45 RO4021 300 650W 230V 50Hz 50 RO4021 450 55 -
RO40 Industrial Reverse Osmosis System
Technical Data:Price on request Read more- Output 300 to 2000 liters / hour ( @15° C water temperature )
- Dimensions approx. WxDxH. (see table)
- Membrane IEM 4040 XLE ( extra low energy PA membrane ) or XHR
- Membrane housing · ( stainless steel pressure vessel )
- Stainless steel centrifugal pump 400V AC, low-noise, multi-stage 2.2 kW ( see table )
Type Output Liters /h Voltage Power draw ( without options )
Weight approx. kg Dimensions W x D x H in mm RO40401 300 650W 230V 50Hz 80 400 x 400 x 1350 RO40402 600 2.2 KW 400V 50Hz 100 400 x 400 x 1350 RO40403 800 115 400 x 510 x 1350 RO40404 1000 130 400 x 650 x 1350 RO40405 1200 145 400 x 790 x 1350 RO40406 1450 160 400 x 650 x 1350 RO40407 1650 175 600 x 800 x 1350 RO40408 1850 190 600 x 800 x 1350 -
LabWasserZentrale – Ultrapure Water Treatment System
Price on request Read more- Ultrapure Water Treatment System - Complete Water Treatment Solution for Laboratory Facilities
- Application area: Research / Laboratory / Medicine
- Product water quality: 18.2 MΩ x cm Class 1 ( ASTM Standard )
- Permeate properties:
- - Conductivity of the product > 18.2 MΩ x cm ( 0.055 µS/cm )
- - Silicate content < 0.1 ppm- TOC < 30 ppb
- Dimensions:
- Dimensions approx. WxDxH 600 x 700 x 1800 ( in mm )
- Basic configuration:
- Stage 1 reverse osmosis system „free-standing unit Type RO4040x“
- Stage 2 reverse osmosis system „free-standing unit Type RO4021x“
- Stage 3 electrodeionization ( EDI )
- Stage 4 polishing
- Touch screen control
-
OSL2S Ultrapure Water Reverse Osmosis System
Technical Data:Price on request Read more- up to 3-stage reverse osmosis water treatment system
- Output up to 60 L/h @ 10°C feed water
- Permeate: - Conductivity of the product < 0.1 μS/cm - Silicate content < 0.1 ppm - TDS < 1 ppm
- Dimensions approx. WxDxH 600x600x805 ( in mm )
Type Output Liters /h Dimensions W x D x H in mm OSL_2S10 10 298 x 600 x 725 OSL_2S20 20 OSL_2S50 50 -
1-Stage 4000L/h Reverse Osmosis Water Treatment System
Price on request Read more- Reverse osmosis water treatment system Type RO84
- 1-stage reverse osmosis water treatment system RO84
- Membrane IEM8040 (low energy PA membrane )
- Membrane housing · ( GFK pressure vessel )
- Output 6000 liters / hour @15° C water temperature
- Stainless steel centrifugal pump 400V AC, low-noise, multi-stage
-
2-Stage Reverse Osmosis Water Treatment System RO805-802
Price on request Read more- Wastewater treatment system Type RO805-802
- 2-stage reverse osmosis water treatment system RO805-802
- Membrane IEM8040 (high rejection PA membrane ) or XHR
- Membrane housing · ( GFK pressure vessel )
- Stainless steel centrifugal pump 400V AC, low-noise, multi-stage
-
2-Stage Reverse Osmosis Water Treatment System RO806-804
Price on request Read more- Wastewater treatment system Type RO806-804
- 2-stage reverse osmosis water treatment system RO806-804
- Membrane IEM8040 (high rejection PA membrane ) or XHR
- Membrane housing · ( GFK pressure vessel )
- Stainless steel centrifugal pump 400V AC, low-noise, multi-stage
-
Type RO83 1-Stage Reverse Osmosis Water Treatment System
Price on request Read more- Reverse osmosis water treatment system Type RO83
- 1-stage reverse osmosis water treatment system RO83
- Membrane IEM8040 (low energy PA membrane )
- Membrane housing · ( GFK pressure vessel )
- Output 4000 liters / hour @15° C water temperature
- Stainless steel centrifugal pump 400V AC, low-noise, multi-stage
-
ROWZ Industrial Reverse Osmosis System
Technical Data:Price on request Read more- Output 150 to 1000 liters / hour ( @15° C water temperature )
- Dimensions approx. WxDxH. (see table)
- Membrane IEM 4040 XLE ( extra low energy PA membrane ) or XHR
- Membrane housing · ( stainless steel pressure vessel )
- Stainless steel centrifugal pump 230 /400V AC, low-noise, ( see table )
-
2-Stage Reverse Osmosis Water Treatment System RO802-802
Price on request Read more- Wastewater treatment system Type RO806-804
- 2-stage reverse osmosis water treatment system RO806-804
- Membrane IEM8040 (high rejection PA membrane ) or XHR
- Membrane housing · ( GFK pressure vessel )
- Stainless steel centrifugal pump 400V AC, low-noise, multi-stage
-
3-Stage 20 L/h EDI Ultrapure Water Reverse Osmosis System
3-Stage 20 Liter / Hour Ultrapure Water Reverse Osmosis EDI Water Treatment System (All-in-One solution)Price on request Read more- Application area: Research / Laboratory / Medicine
- 20 liters / hour (< 1 µs/cm and TOC <0.3 mg/l @15° C water temperature)
- Basic configuration:
- Stage 1 reverse osmosis system „free-standing unit Type RO4040x”
- Stage 2 reverse osmosis system „free-standing unit Type RO4021x”
- Stage 3 electrodeionization ( EDI )
- Touch screen control. An EDI unit with matching output is used for the permanent production of ultrapure water. This technology works through electrodialysis and electrodeionization. Removing bacteria in ultrapure water applications is especially critical in medical and laboratory procedures. Ultrafiltration technology ( hollow fiber membrane ) is used to kill and remove bacterial contamination with the help of ultraviolet irradiation. When integrated into a ring main, the system can also supply the entire consumer base of a laboratory facility or other requirement and permanently prevent the growth and formation of bacteria through UV and ultrafiltration.
- Basic configuration:
-
3-Stage 250 L/h EDI Ultrapure Water Reverse Osmosis System
Price on request Read more- Ultrapure Water Treatment System – Complete Water Treatment Solution for Laboratory Facilities
- Application area: Research / Laboratory / Medicine
- Product water quality: 18.2 MΩ x cm ( Class 1 ASTM Standard )
- Permeate properties:
- – Conductivity of the product > 18.2 MΩ x cm ( 0.055 µS/cm )
- – Silicate content < 0.1 ppm- TOC < 30 ppb
- Basic configuration:
- Stage 1 reverse osmosis system „free-standing unit Type RO4040x“
- Stage 2 reverse osmosis system „free-standing unit Type RO4021x“
- Stage 3 electrodeionization ( EDI )
- Stage 4 polishing
- Touch screen control
-
2-Stage Reverse Osmosis Water Treatment System RO Standalone Unit
2-Stage Reverse Osmosis Water Treatment System RO Free-Standing Unit Output 2 m³/h Feed water ( wastewater or brackish water ): @25° C water temperature 15000 PPM NaClPrice on request Read more -
RO2S Ultrapure Water Reverse Osmosis System
Technical Data:Price on request Read more- up to 3-stage ultrapure water treatment system
- Output 100 liters/ h @ 10°C
- Permeate: - Conductivity of the product < 1* µS/cm - Silicate content < 0.1 ppm - TDS < 1 ppm
- Dimensions approx. WxDxH 1000 x 1700 x 1400 ( in mm )
- Stage 1 reverse osmosis system „free-standing unit Type RO40401
- Stage 2 reverse osmosis system „free-standing unit Type RO 40401
- Stage 3 mixed-bed resin + EP with lab resin
-
3-Stage 225 L/h EDI Ultrapure Water Reverse Osmosis System
Price on request Read more- Ultrapure Water Treatment System – Complete Water Treatment Solution for Laboratory Facilities
- Application area: Research / Laboratory / Medicine
- Product water quality: 18.2 MΩ x cm ( Class 1 ASTM Standard )
- Permeate properties:
- – Conductivity of the product > 18.2 MΩ x cm ( 0.055 µS/cm )
- – Silicate content < 0.1 ppm- TOC < 30 ppb
- Basic configuration:
- Stage 1 reverse osmosis system
- Stage 2 reverse osmosis system
- Stage 3 electrodeionization ( EDI )
- Stage 4 polishing
- Touch screen control
-
BSL Industrial Reverse Osmosis System
Technical Data:Price on request Read more- Output 150 to 450 liters / hour ( Direct-Flow reverse osmosis system )
- Stainless steel membrane housing
- Membrane Type 4021 IEM
- Rotary vane pump 230V AC Type P211
Type Output Liters /h Voltage Power draw ( without options ) Weight approx. kg Dimensions W x D x H in mm BSL150 150 550W 230V 50Hz 25 298 x 600 x 725 BSL300 300 650W 230V 50Hz 30 BSL450 450 40 -
LPW (Lab Pure Water System)
Price on request Read moreLPW (Lab Pure Water System):
- The LPW is able to dispense a freely adjustable amount of water.
- Water can be drawn in the milliliter range.
- Product water quality ( Class 1 ASTM):
- Conductivity 0.056 µs/cm
- Resistivity 18.0 MΩxcm
- Total Organic Carbon ( TOC) Max. 50 µg/L
- The quantity can be selected via the front outlet or the external withdrawal point.
-
LS Industrial Reverse Osmosis System
Price on request Read more- Output: up to 80 liters / hour ( 15°C water temp. )
- Membrane IEM 380 or 2514 ( depending on version )
- Membrane housing Type 2012 or 2514 ( depending on version )
- Stainless steel rotary vane pump 230V AC TYPE P210
Type
Output Liters /h Voltage
Weight approx. kg Dimensions W x D x H in mm LS10 10 235W 230V 50Hz 25 360 x 500 x 460 LS20 20 26 LS30 30 27 LS40 40 28 LS60 60 30 -
LS2S Ultrapure Water Reverse Osmosis System
Technical Data: ( LS2S industrial reverse osmosis system water treatment by reverse osmosis )Price on request Read more- up to 3-stage reverse osmosis water treatment system
- Output up to 10 L/h @ 10°C feed water
- Permeate: - Conductivity of the product Class 1 ( ASTM Standard ) 18.2 MΩ x cm ( 0.055 µS/cm ) - TDS < 1 ppm
- Dimensions approx. WxDxH 360x500x460 ( in mm )
- Stage 1: reverse osmosis system „Type LS“
- Stage 2 reverse osmosis system „Type OS“
- Stage 3 MB or EDI (inline electrodeionization system )
Type Output Liters /h Dimensions W x D x H in mm LS2S7 7 360x500x460 LS2S10 10 -
LWZ LabWasserZentrale – Ultrapure Water Treatment System
Price on request Read more- LWZ Ultrapure Water Treatment System - Complete Water Treatment Solution for Laboratory Facilities
- Application area: Research / Laboratory / Medicine
- Product water quality: 18.2 MΩ x cm Class 1 ( ASTM Standard )
- Permeate properties:
- - Conductivity of the product > 18.2 MΩ x cm ( 0.055 µS/cm )
- - Silicate content < 0.1 ppm- TOC < 30 ppb
- Basic configuration:
- Stage 1 reverse osmosis system „free-standing unit Type RO4040x“
- Stage 2 reverse osmosis system „free-standing unit Type RO4021x“
- Stage 3 electrodeionization ( EDI )
- Stage 4 polishing
- Touch screen control
-
Mobil Clean Compact 300L Window/Glass Cleaning
MobilClean Compact 300 - ideal for mobile water treatment for glass / façade cleaning Technical Data:Price on request Read more- Output up to 300 liters / hour
- Mobile system on wheels, also ideal for rough terrain
- Stainless steel housing
- Stainless steel pump 230V AC
- Backwashable pre-filter
- With integrated flushing system
- all connections in 3/4 inch male thread
- Voltage 230V AC 50 Hz, max. 10A
- Power draw 645W
- L x W x H 800 x 450 x 500 mm ( without handle )
- 800 x 450 x 850 mm ( with handle, removable! )
- Weight: approx. 30 kg
- Inlet pressure Min. 1 bar ( feed water )
- Temperature 5° C to 30° C ( performance figures at 15° C )
- Maximum free chlorine: 0.1 mg/l
-
Mobil Clean Compact 450L Window/Glass Cleaning
MobilClean Compact 450 - ideal for mobile water treatment for glass / façade cleaning Technical Data:Price on request Read more- Output up to 450 liters / hour
- Mobile system on wheels, also ideal for rough terrain
- Stainless steel housing
- Stainless steel pump 230V AC
- Backwashable pre-filter
- With integrated flushing system
- all connections in 3/4 inch male thread
- Voltage 230V AC 50 Hz, max. 10A
- Power draw 645W
- L x W x H 800 x 450 x 500 mm ( without handle )
- 800 x 450 x 850 mm ( with handle, removable! )
- Weight: approx. 40 kg
- Inlet pressure Min. 1 bar ( feed water )
- Temperature 5° C to 30° C ( performance figures at 15° C )
- Maximum free chlorine: 0.1 mg/l
-
MobilClean Mobile Reverse Osmosis System
Technical Data:Price on request Read more- Output: 400 liters / hour ( 15°C water temp. )
- Membrane IEM 4040 XLE
- Membrane housing Type 4040 stainless steel
- Stainless steel rotary vane pump 230V AC TYPE BM
Type
Output Liters/h Voltage
Weight Mobil Clean 40401 400 1500W 230V 50Hz 60 kg W 530mm D 500mm H 1300mm -
MobilClean-H Mobile Reverse Osmosis System
Technical Data:Price on request Read more- Output: 400 liters / hour ( 15°C water temp. )
- Membrane IEM 4040 XLE
- Membrane housing Type 4040 stainless steel
- Stainless steel rotary vane pump 230V AC TYPE BM
Type
Output Liters/h Voltage
Weight Mobil Clean 40401 400 1500W 230V 50Hz 60 kg W 530mm D 500mm H 1300mm