3-Stage 225 L/h EDI Ultrapure Water Reverse Osmosis System

Price on request

  • Ultrapure Water Treatment System – Complete Water Treatment Solution for Laboratory Facilities
  • Application area: Research / Laboratory / Medicine
  • Product water quality: 18.2 MΩ x cm ( Class 1 ASTM Standard )
  • Permeate properties:
    • – Conductivity of the product > 18.2 MΩ x cm ( 0.055 µS/cm )
    • – Silicate content < 0.1 ppm- TOC < 30 ppb
  • Basic configuration:
    • Stage 1 reverse osmosis system
    • Stage 2 reverse osmosis system
    • Stage 3 electrodeionization ( EDI )
    • Stage 4 polishing
    • Touch screen control

Description

Specifications 3-Stage 225 L/h EDI Ultrapure Water Reverse Osmosis System:

Type: 3-Stage 225 Liter / Hour Ultrapure Water Reverse Osmosis EDI Water Treatment System
Output: 225 liters / hour (<0.1 µs/cm @15° C water temperature
Feed water tap water quality:
Softened @ 1 ° dH
Conductivity @ 600µs/cm
Based on the customer’s drinking water analysis.
Dimensions: approx. 1100*700*1820mm WxDxH (system only, without base)
Screen backwash filter
(fine filter) 1/2″
Dirt particles and foreign matter are reliably filtered out by a fine, dimensionally stable filter screen. Thanks to the backwash function, this filter is completely cleaned again in the shortest possible time.
Pressure reducer Pressure reducer
Backflow preventer The backflow preventer secures the drinking water supply by preventing non-potable water from flowing back into the public water supply network. Installed between the public water supply network and the private consumer network, the backflow preventer creates a separation and thus prevents contact between the two water networks. It protects the public water supply network against downstream overpressure, reverse pressure conditions and water backflow. According to standard EN 12729 per EN 1717.

You do not need this option if you already have a backflow preventer installed.

Antiscalant dosing station Antiscalant dosing station with proportional dosing adapted to the online output of the reverse osmosis system (stage 1)
Dosing system, complete with 60 liter tank + dosing pump, foot valves, check valves, mounting and hoses.
Control via the reverse osmosis PLC including a dosing agent monitoring.
1x delivery rate: 6 bar – 1.5 liters to 20 bar – 0.4 liters
1x tank: 60 liters
1x suction lance with low-level indicators
1x agitator
Incl. dry-run protection
Approx. 3 ppm antiscalant is to be dosed; the exact dosing quantity is calculated and communicated after the order and a full feed water analysis.
Pre-filter:
Sediment filter Sediment filter
integrated pre-filter housing 2.5
– incl. filter housing wrench
– 5µ fine filter fitted
– including piping with the system
– with mounting bracket
Carbon filter integrated pre-filter housing 2.5
– incl. filter housing wrench
– carbon filter fitted
– including piping with the system
– with mounting bracket
System type 3-Stage 225 Liter / Hour Ultrapure Water Reverse Osmosis EDI Water Treatment System (All-in-One solution)
Output: 225 liters / day (<0.1 µs/cm @15° C water temperature
without item 2: conductivity < 0.1 µs/cm @15° C water temperature
Dimensions: 1100*700*1820mm WxDxH.
Aluminum frame without cover.
A complete solution from tap water to ultrapure water in a single system with all the required components.
PLC control: IEM computer controller with USB connection and optional remote monitoring and administration via internet
Dry-run protection: Yes
Stage 1 Reverse osmosis water treatment system Type 442
Output: 500 liters / hour (99% rejection @15° C water temperature)
Membrane IEM XLE4040 (extra low energy PA membrane)
Membrane housing: Stainless steel pressure vessel, PE end caps
Pump: RO pump, stainless steel, low-noise
Mounting – Design: mounted on aluminum frame
Flow sensors: 2x active digital flow transmitter
(1: product, 1: concentrate)
Pressure sensors: 2x active digital pressure transmitter 0-16 bar
(inlet pressure, operating pressure)
Dry-run protection: Yes
Flushing system: Automatic flushing system (solenoid valve)
Conductivity display: conductivity monitoring on the permeate
Permeate rejection with permeate reject system
Stage 2 Reverse osmosis water treatment system Type 441
Output: 300 liters / hour (99% rejection @15° C water temperature)
Membrane IEM XLE4040 (extra low energy PA membrane)
Membrane housing: Stainless steel pressure vessel, PE end caps
Pump: Booster pump, stainless steel
Conductivity display: conductivity display on the permeate
Mounting – Design: Aluminum frame
Flow sensors: 1x active digital flow transmitter
(1: product)
Pressure sensors: 1x active digital pressure transmitter 0-16 bar
(operating pressure)
Dry-run protection: Yes
Stage 3 EDI (internal)
Output: 225 liters / hour <0.1 µs/cm
Feed water inlet: Solenoid valve on the water inlet 230 V 50Hz
Connections: Permeate 3/4″ male thread / Feed water 3/4″ male thread
Concentrate funnel DN50 (standard drain fitting)
Shutdown: Signal (without float switch)
Limits: Max. salt content in feed water 3000 µS/cm (design basis 750 µs/cm)
Min. inlet pressure 1 bar feed water
Temperature 4° C to 30° C
Feed water quality: 5µ filtered, drinking water
Maximum free chlorine: 0.1 mg/l. Installation site should have:
Floor drain & ventilation
Fault signal: Collective fault signal (potential-free)
Monitoring interactive monitoring system and remote administration
Touch Screen interactive touch screen system + remote monitoring
Monitoring system with PLC computer control
control cabinet with RS232 or USB interface for programming and remote administration via internet
1x conductivity display transmitter on the permeate
3x active digital flow transmitter
(1: product, 1: concentrate, 1: recirculation)
3x active digital pressure transmitter 0-16 bar. Further functions:
– filter change indicator
– status display of pressure and flow
– quality monitoring
– error log. The current status of the system can be monitored remotely by the customer as needed with the help of client software (monitoring). A DHCP-capable internet connection is required at the system via a connected RJ-45 cable on the customer’s side for this.
Changes to the software can only be made remotely by the manufacturer (IEM) after mutual agreement. The customer does not receive access to the PLC programming; this remains reserved for the manufacturer (IEM).
Conveying system without storage tank:
Pump Product water conveying system
Diaphragm pump type P288D
Working pressure: up to 7 bar
Working flow @ 3 bar 288 L/h
Free flow: 510 L/h
Filter 0.2µ Sterile filter 0.2µ
Filter type 0.2 µ cartridge filter
Material: Polypropylene
2.5 x 10 inch ( filter area 0.65 m² )
Operating temp. up to 65° C
Operating pressure 4.2 bar ( max. differential 2 bar)

Other Products:

2-Stage Reverse Osmosis Water Treatment System RO Free-Standing Unit

RO40 Industrial Reverse Osmosis System

3-Stage 20 L/h EDI Ultrapure Water Reverse Osmosis System

2-Stage Reverse Osmosis Water Treatment System RO806-804

Additional information

System Type
Gehäuseart
Housing Type

Output

Reviews

There are no reviews yet.

Be the first to review “3-Stage 225 L/h EDI Ultrapure Water Reverse Osmosis System”

Your email address will not be published. Required fields are marked *