Description
Specifications 2-Stage Reverse Osmosis Water Treatment System RO806-804:
| Type: | 2-Stage Reverse Osmosis Water Treatment System RO806-804 | ||
| Output: | Output 160m³/day raw water 7.05 m³/h ( @35° C water temperature ) Feed water quality wastewater: COD 150mg/l NH4—N 0.5-50mg/l |
||
| Dimensions: | Free-standing stainless steel frame combined with aluminum profiles LxWxH 1500x7200x1800 mm Dimensions for RO system only, without options and tanks |
||
| PLC control: Monitoring: |
interactive 7″ touch screen monitoring system IEM computer controller with USB connection and optional remote control via internet interactive touch screen monitoring system with IEM PLC computer control with internet remote administration option control cabinet with RS232 or USB interface for programming and remote administration via internet (optional) 1x conductivity display transmitter on the permeate** 3x active digital flow transmitter bar (1: product, 1: concentrate, 1: recirculation) 3x active digital flow transmitter 0-16 bar |
||
| Stage 1 | Reverse osmosis water treatment system Type 806 | ||
| Output: | 160m³/day concentrate (7.05m³/h) (99% rejection @25° C water temperature ) recovery 70% Concentrate 2.46 m³/h |
||
| Membrane | extra high rejection membrane ( PA membrane ) | ||
| Membrane housing: | GFK pressure vessel | ||
| Pump: | a- RO pump, stainless steel centrifugal pump 400V AC, low-noise, multi-stage b- CY pump, stainless steel centrifugal pump 400V AC, low-noise, multi-stage |
||
| Conductivity display: | conductivity monitoring on the permeate | ||
| Mounting – Design: | mounted on stainless steel frame | ||
| Flow sensors: | 2x active digital flow transmitter (1: product, 1: concentrate) |
||
| Pressure sensors: | 2x active digital pressure transmitter 0-16 bar ( inlet pressure, operating pressure ) |
||
| Dry-run protection: | Yes | ||
| Concentrate Displacement: | Concentrate Displacement unit If the product water tank ( the product water tank is not included in the offer and scope of delivery ) is full, the RO system must be flushed before standby due to the highly concentrated feed water. This must not remain in the system after standby and must be flushed out. Concentrate Displacement tank: 200 liters Float switch Multi-stage, horizontal centrifugal pump 230V AC Type P510. The Concentrate Displacement unit performs this task via the PLC control with its own special programming and with its own tank and pump. The permeate is supplied from the product water. |
||
| Stage 2 | Reverse osmosis water treatment system Type 804 | ||
| Output: | Output 5.74 m³/h feed water 4.59 m³/h product water ( @35° C water temperature ) recovery up to 80% The concentrate from stage 2 is fed back into stage 1. ( stage 2 without concentrate ) |
||
| Membrane | extra high rejection membrane ( PA membrane ) | ||
| Membrane housing: | GFK pressure vessel | ||
| Pump: | a- RO pump, stainless steel centrifugal pump 400V AC, low-noise, multi-stage b- CY pump, stainless steel centrifugal pump 400V AC, low-noise, multi-stage |
||
| Conductivity display: | conductivity display on the permeate as text | ||
| Mounting – Design: | mounted on stainless steel frame | ||
| Flow sensors: | 1x active digital flow transmitter (1: product / concentrate is calculated by the PLC ) |
||
| Pressure sensors: | 1x active digital pressure transmitter 0-16 bar ( inlet pressure, operating pressure ) |
||
| Permeate rejection | with permeate reject system | ||
| Feed water inlet: | solenoid valve on the water inlet 230 V 50Hz | ||
| Connections: | Permeate 1 1/2″ female thread / Concentrate 1 1/2″ female thread / Feed water 1 1/2″ female thread | ||
| Shutdown: | Float switch | ||
| Float switch with 10m cable, connected and programmed for shutdown |
|||
| Fault signal: | Collective fault signal ( potential-free ) | ||
| Limits: | Feed water quality wastewater: from the MBR with the following parameters:
COD 150mg/l Min. inlet pressure 1 bar feed water |
||
| Pre-filter | |||
| Sediment filter integrated pre-filter housing … inch – incl. filter housing wrench – 5µ fine filter fitted – including piping with the system – with mounting bracket |
|||
| CIP | Cleaning in Production ( chemical cleaning ) Tank 200 liters Pump, stainless steel horizontal centrifugal pump 550 W 230 V AC Cartridge filter 2.5×10 50µ. During normal operation, the membranes of the reverse osmosis system can become unusable due to mineral, biological and insoluble organic particles, resulting in a reduction of product water and/or a reduction in desalination. If a decline in water quality (conductivity) occurs in any of the units, or if changes in pressure parameters or flow rate occur, a chemical cleaning of the modules must be carried out. |
||
| Cleaning in Production ( chemical cleaning ) 3-way valves and piping for stage 1 only. Cleaning in Production ( chemical cleaning ) 3-way valves and piping for stage 1 only |
|||
| Cleaning in Production ( chemical cleaning ) 3-way valves and piping for stage 2 only |
|||
| Antiscalant dosing station | Antiscalant dosing station with proportional dosing adapted to the online output of the reverse osmosis system ( stage 1) Dosing system, complete with 60 liter tank + dosing pump, foot valve, check valves, mounting and hoses. Control via the reverse osmosis PLC including a dosing agent monitoring. 1x delivery rate: 6 bar – 1.5 liters to 20 bar – 0.4 liters 1x tank: 60 liters 1x suction lance with low-level indicators 1x agitator Incl. dry-run protection Approx. 3 ppm antiscalant is to be dosed; the exact dosing quantity is calculated and communicated after the order and a full feed water analysis. |
||
| Sodium bisulfite dosing station | Sodium bisulfite dosing station with proportional dosing adapted to the online output of the reverse osmosis system ( stage 1 and 2 ) Dosing system, complete with 60 liter tank + dosing pump, foot valve, check valves, mounting and hoses. Control via the reverse osmosis PLC including a dosing agent monitoring. 1x delivery rate: 6 bar – 1.5 liters to 20 bar – 0.4 liters 1x tank: 60 liters 1x suction lance with low-level indicators 1x agitator Incl. dry-run protection, for the elimination of chlorine during operation and prevention of biological growth in standby mode. |
||
| Product water stage separation option if the quality of the stage 1 product water is sufficiently good, this option allows stage 2 to be taken out of operation. 10-1 Pump(s) for stage 1 is adjusted; additional fittings separate stage 2 from stage 1.
( regular flushing and dosing of disinfectant )Note: In general, the quality of the stage 1 product water with active stage separation will be worse than when both stages are in operation without separation. |
|||
| Sediment filter 4 x 20 inch Big Blue 5µ |
|||
List of Related Products:
2-Stage Reverse Osmosis Water Treatment System RO805-802
2-Stage Reverse Osmosis Water Treatment System RO Free-Standing Unit

Reviews