2-Stage Reverse Osmosis Water Treatment System RO806-804

Price on request

  • Wastewater treatment system Type RO806-804
  • 2-stage reverse osmosis water treatment system RO806-804
  • Membrane IEM8040 (high rejection PA membrane ) or XHR
  • Membrane housing · ( GFK pressure vessel )
  • Stainless steel centrifugal pump 400V AC, low-noise, multi-stage

 

Description

Specifications 2-Stage Reverse Osmosis Water Treatment System RO806-804:

Type: 2-Stage Reverse Osmosis Water Treatment System RO806-804
Output: Output 160m³/day raw water 7.05 m³/h
( @35° C water temperature )
Feed water quality wastewater:
COD 150mg/l
NH4—N 0.5-50mg/l
Dimensions: Free-standing stainless steel frame combined with aluminum profiles
LxWxH 1500x7200x1800 mm
Dimensions for RO system only, without options and tanks
PLC control:
Monitoring:
interactive 7″ touch screen monitoring system
IEM computer controller with USB connection and optional remote control via internet
interactive touch screen monitoring system with IEM PLC computer control with internet remote administration option
control cabinet with RS232 or USB interface for programming and remote administration via internet (optional)
1x conductivity display transmitter on the permeate**
3x active digital flow transmitter bar (1: product, 1: concentrate, 1: recirculation)
3x active digital flow transmitter 0-16 bar
Stage 1 Reverse osmosis water treatment system Type 806
Output: 160m³/day concentrate (7.05m³/h)
(99% rejection @25° C water temperature )
recovery 70%
Concentrate 2.46 m³/h
Membrane extra high rejection membrane ( PA membrane )
Membrane housing: GFK pressure vessel
Pump: a- RO pump, stainless steel centrifugal pump 400V AC, low-noise, multi-stage
b- CY pump, stainless steel centrifugal pump 400V AC, low-noise, multi-stage
Conductivity display: conductivity monitoring on the permeate
Mounting – Design: mounted on stainless steel frame
Flow sensors: 2x active digital flow transmitter
(1: product, 1: concentrate)
Pressure sensors: 2x active digital pressure transmitter 0-16 bar
( inlet pressure, operating pressure )
Dry-run protection: Yes
Concentrate Displacement: Concentrate Displacement unit
If the product water tank ( the product water tank is not included in the offer and scope of delivery ) is full, the RO system must be flushed before standby due to the highly concentrated feed water. This must not remain in the system after standby and must be flushed out. Concentrate Displacement tank: 200 liters
Float switch
Multi-stage, horizontal centrifugal pump 230V AC Type P510. The Concentrate Displacement unit performs this task via the PLC control with its own special programming and with its own tank and pump. The permeate is supplied from the product water.
Stage 2 Reverse osmosis water treatment system Type 804
Output: Output 5.74 m³/h feed water
4.59 m³/h product water
( @35° C water temperature ) recovery up to 80%
The concentrate from stage 2 is fed back into stage 1.
( stage 2 without concentrate )
Membrane extra high rejection membrane ( PA membrane )
Membrane housing: GFK pressure vessel
Pump: a- RO pump, stainless steel centrifugal pump 400V AC, low-noise, multi-stage
b- CY pump, stainless steel centrifugal pump 400V AC, low-noise, multi-stage
Conductivity display: conductivity display on the permeate as text
Mounting – Design: mounted on stainless steel frame
Flow sensors: 1x active digital flow transmitter
(1: product / concentrate is calculated by the PLC )
Pressure sensors: 1x active digital pressure transmitter 0-16 bar
( inlet pressure, operating pressure )
Permeate rejection with permeate reject system
Feed water inlet: solenoid valve on the water inlet 230 V 50Hz
Connections: Permeate 1 1/2″ female thread / Concentrate 1 1/2″ female thread / Feed water 1 1/2″ female thread
Shutdown: Float switch
Float switch with 10m cable, connected and programmed
for shutdown
Fault signal: Collective fault signal ( potential-free )
Limits: Feed water quality wastewater: from the MBR with the following parameters:

COD 150mg/l
NH4—N 0.5-50mg/l

Min. inlet pressure 1 bar feed water
Temperature 4° C to 40° C
Feed water quality: ultrafiltration performed
Maximum chlorine content: 0.1 mg/l

Pre-filter
Sediment filter
integrated pre-filter housing … inch
– incl. filter housing wrench
– 5µ fine filter fitted
– including piping with the system
– with mounting bracket
CIP Cleaning in Production ( chemical cleaning )
Tank 200 liters
Pump, stainless steel horizontal centrifugal pump 550 W 230 V AC
Cartridge filter 2.5×10 50µ. During normal operation, the membranes of the reverse osmosis system can become unusable due to mineral, biological and insoluble organic particles, resulting in a reduction of product water and/or a reduction in desalination.
If a decline in water quality (conductivity) occurs in any of the units, or if changes in pressure parameters or flow rate occur, a chemical cleaning of the modules must be carried out.
Cleaning in Production ( chemical cleaning )
3-way valves and piping for stage 1 only. Cleaning in Production ( chemical cleaning )
3-way valves and piping for stage 1 only
Cleaning in Production ( chemical cleaning )
3-way valves and piping for stage 2 only
Antiscalant dosing station Antiscalant dosing station with proportional dosing adapted to the online output of the reverse osmosis system ( stage 1)
Dosing system, complete with 60 liter tank + dosing pump, foot valve, check valves, mounting and hoses.
Control via the reverse osmosis PLC including a dosing agent monitoring.
1x delivery rate: 6 bar – 1.5 liters to 20 bar – 0.4 liters
1x tank: 60 liters
1x suction lance with low-level indicators
1x agitator
Incl. dry-run protection
Approx. 3 ppm antiscalant is to be dosed; the exact dosing quantity is calculated and communicated after the order and a full feed water analysis.
Sodium bisulfite dosing station Sodium bisulfite dosing station with proportional dosing adapted to the online output of the reverse osmosis system ( stage 1 and 2 )
Dosing system, complete with 60 liter tank + dosing pump, foot valve, check valves, mounting and hoses.
Control via the reverse osmosis PLC including a dosing agent monitoring.
1x delivery rate: 6 bar – 1.5 liters to 20 bar – 0.4 liters
1x tank: 60 liters
1x suction lance with low-level indicators
1x agitator
Incl. dry-run protection, for the elimination of chlorine during operation and prevention of biological growth in standby mode.
Product water stage separation option
if the quality of the stage 1 product water is sufficiently good, this option allows stage 2 to be taken out of operation. 10-1 Pump(s) for stage 1 is adjusted; additional fittings separate stage 2 from stage 1.

  • PLC program is adjusted for 1-stage operation.
  • CIP system is adjusted.
  • Operational safety of stage 2 is adjusted and ensured

 

( regular flushing and dosing of disinfectant )Note: In general, the quality of the stage 1 product water with active stage separation will be worse than when both stages are in operation without separation.

Sediment filter
4 x 20 inch Big Blue 5µ

List of Related Products:

2-Stage Reverse Osmosis Water Treatment System RO805-802

2-Stage Reverse Osmosis Water Treatment System RO Free-Standing Unit

 

Additional information

System Type
Gehäuseart
Housing Type

Output

Reviews

There are no reviews yet.

Be the first to review “2-Stage Reverse Osmosis Water Treatment System RO806-804”