Technical Data:

  • Output 150 to 450 liters / hour ( Direct-Flow reverse osmosis system )
  • Stainless steel membrane housing
  • Membrane Type 4021 IEM
  • Rotary vane pump 230V AC Type P211

 

Type Output
Liters /h
Voltage
Power draw
( without options )
Weight
approx. kg
Dimensions
W x D x H
in mm
BSL150 150 550W 230V 50Hz 25 298
x
600
x
725
BSL300 300 650W 230V 50Hz 30
BSL450 450 40

Description

Specifications BSL Industrial Reverse Osmosis System:

Reverse Osmosis System Type BSL – Reverse Osmosis Water Treatment

Type

BSL150 BSL300 BSL450
Output Liters/h 150 300 450
Dimensions W x D x H mm 500 x 680 x 340
Bypass (automatic) Option
Conveying system none
Mixing valve Option

Touch Screen Display

Option
Castors none
Shutdown system Float switch Option
Pressure switch Option
Flow switch Standard
Storage tank open none
Pressure tank Option

Technical Data:
( BSL industrial reverse osmosis water treatment system )

  • Output: 150 to 450 liters/hour (at 15°C water temperature)
  • Stainless steel membrane housing
  • Membrane Type 4021 IEM XLE
  • Stainless steel rotary vane pump 230V AC Type P211
  • Automatic low-pressure switch
  • 3x active digital flow transmitter ( 1: product, 1: concentrate, 1: recirculation )
  • 2x active digital pressure transmitter 0-16 bar ( inlet pressure, operating pressure )
  • IEM PLC controller with remote administration option via USB or serial via internet
  • Conductivity display on the permeate in µS/cm ( option )
  • Automatic flushing system
  • Solenoid valve on the water inlet
  • Operating hours counter
  • Stainless steel housing, with stainless steel cover or PE side panels
  • Mixing valve ( option )
  • Automatic bypass system

Connections:

  • all connections in 3/4″ AG

Power Supply:

  • Voltage 230V AC 50 Hz, max. 10A
  • Power draw max. 650 W

Dimensions and Weight:

  • Width 500 x Depth 680 x Height 340 ( mm )
  • Weight: up to 30 kg depending on configuration

Limits:

  • Max. salt content in feed water 600 ppm
  • °dH hardness – recovery
    0° = 70%
    10° = 50%
    15° = 40%
  • Inlet pressure Min. 1 bar / Max. 4 bar ( feed water )
  • Temperature 5° C to 35° C
    ( performance figures at 15° C )
  • Feed water quality: drinking water ( 5µ filtered )

List of Related Products:

LabWasserZentrale Ultrapure Water Treatment System

OSL2S Ultrapure Water Reverse Osmosis System

RO40 Industrial Reverse Osmosis System

Mobil Clean Compact 300L Window/Glass Cleaning

Additional information

Gehäuseart
System Type
Housing Type

Output

Reviews

There are no reviews yet.

Be the first to review “BSL Industrial Reverse Osmosis System”

Your email address will not be published. Required fields are marked *