Showing 1–4 of 15 results
-
LS Industrial Reverse Osmosis System
Read more- Output: up to 80 liters / hour ( 15°C water temp. )
- Membrane IEM 380 or 2514 ( depending on version )
- Membrane housing Type 2012 or 2514 ( depending on version )
- Stainless steel rotary vane pump 230V AC TYPE P210
Type
Output Liters /h Voltage
Weight approx. kg Dimensions W x D x H in mm LS10 10 235W 230V 50Hz 25 360 x 500 x 460 LS20 20 26 LS30 30 27 LS40 40 28 LS60 60 30 -
OSL Industrial Reverse Osmosis System
Technical Data:Read more- Output max. up to 450 liters / hour
- Stainless steel membrane housing
- Membrane Type 4021 IEM XLE or XHR
- Rotary vane pump 230V AC Type P211
- Stainless steel housing
- with internal storage tank and conveying system
Type
Output Liters /h Voltage Power draw ( without options )
Weight approx. kg Dimensions W x D x H in mm OSL50 50 235W 230V 50Hz 50 598 x 600 x 725 OSL100 100 OSL150 150 550W 230V 50Hz 55 OSL300 300 650W 230V 50Hz 60 OSL450 450 65 OSL50 Online 50 300W 230V 50Hz 50 598 x 600 x 725 OSL100 Online 100 OSL150 Online 150 550W 230V 50Hz 55 OSL300 Online 300 650W 230V 50Hz 60 OSL450 Online 450 65 -
3-Stage 20 L/h EDI Ultrapure Water Reverse Osmosis System
3-Stage 20 Liter / Hour Ultrapure Water Reverse Osmosis EDI Water Treatment System (All-in-One solution)Read more- Application area: Research / Laboratory / Medicine
- 20 liters / hour (< 1 µs/cm and TOC <0.3 mg/l @15° C water temperature)
- Basic configuration:
- Stage 1 reverse osmosis system „free-standing unit Type RO4040x”
- Stage 2 reverse osmosis system „free-standing unit Type RO4021x”
- Stage 3 electrodeionization ( EDI )
- Touch screen control. An EDI unit with matching output is used for the permanent production of ultrapure water. This technology works through electrodialysis and electrodeionization. Removing bacteria in ultrapure water applications is especially critical in medical and laboratory procedures. Ultrafiltration technology ( hollow fiber membrane ) is used to kill and remove bacterial contamination with the help of ultraviolet irradiation. When integrated into a ring main, the system can also supply the entire consumer base of a laboratory facility or other requirement and permanently prevent the growth and formation of bacteria through UV and ultrafiltration.
- Basic configuration:
-
RO2S Ultrapure Water Reverse Osmosis System
Technical Data:Read more- up to 3-stage ultrapure water treatment system
- Output 100 liters/ h @ 10°C
- Permeate: - Conductivity of the product < 1* µS/cm - Silicate content < 0.1 ppm - TDS < 1 ppm
- Dimensions approx. WxDxH 1000 x 1700 x 1400 ( in mm )
- Stage 1 reverse osmosis system „free-standing unit Type RO40401
- Stage 2 reverse osmosis system „free-standing unit Type RO 40401
- Stage 3 mixed-bed resin + EP with lab resin