Specifications: Reverse Osmosis Water Treatment System Type RO83:
Reverse Osmosis Water Treatment System Type RO83 – 4000 L/h
Output 4000 liters/hour (design basis: 15°C water temperature, per water analysis)
Dimensions approx. W x D x H 4000 x 1000 x 1600 mm (RO system only)
Membrane 8″ / PA membrane
GRP pressure vessel 8″ 20 bar
Stainless steel booster pump
Automatic low-pressure switch (dry-run protection)
IEM computer controller with USB port and optional remote control via internet
Conductivity display on the permeate
Aluminum or stainless steel frame
Automatic flushing system
2x Active digital flow transmitter (1: product, 1: concentrate, 1: recirculation)
2x Active analog pressure transmitter 0-16 Bar (inlet pressure, operating pressure)
Shutdown via float switch (contact only)
Connections:
Permeate: PVC
Concentrate: PVC
Feed water: PVC
Recovery up to 85% (design basis 70% with pre-treatment @ >1000 ppm
feed water quality: tap water 0° dH or with antiscalant)
Max. salt content in feed water 3000 ppm (design basis @1000 ppm)
Min. inlet pressure 1 bar feed water
Temperature 5° to 35° C (design basis @15° C)
Feed water quality: 5µ filtered, with pre-treatment
Maximum iron: 0.115 mg/l (design basis with antiscalant)
Maximum chlorine content: 0.1 mg/l
SDI <3 (if SDI>3, a sand filter must be added)